Last updated November 12, 2026. Lab facts in this guide were checked against each laboratory’s own website on November 12, 2026, and the method descriptions against the harmonized pharmacopoeial sterility text and FDA guidance listed under Sources. Amino Review does not run lab tests, and this is not a ranked list or an endorsement of any lab.

Disclosure: Amino Review earns commissions from some vendors we review (see our Affiliate Disclosure). Affiliate status is not an input to any grade, and this article contains no affiliate links.

A certificate that says 99.2% pure looks like the end of the question. It isn’t. HPLC purity measures how much of the detected material is the expected compound. It does not look for bacteria, and it does not look for endotoxin, the fever-causing residue bacteria leave behind. Those are separate tests with separate methods, and a certificate covers only the tests listed on it.

The gap is not theoretical. On November 6, 2026, Health Canada warned that its lab testing of seized, unauthorized injectable peptides sold online had found bacteria, including Acinetobacter species. In total it seized more than 11,400 vials from one overseas supplier and two Canadian online retailers. This guide explains what sterility and endotoxin tests actually measure, why the method line on a certificate matters more than the word “sterility,” and which of nine testing labs say they offer which test.

The short version

  • Purity, sterility and endotoxin are three different tests. A 99% purity figure says nothing about either of the other two.
  • The compendial sterility test (USP <71>, harmonized with the European and Japanese pharmacopoeias) is a culture test: two growth media, incubated for not less than 14 days.
  • Many labs sell faster “sterility” screens instead: PCR, DNA microarray or microbial counts. They can be useful. They are not the same method, and the certificate should say which one was run.
  • Endotoxin testing (USP <85>) reports a number in endotoxin units (EU). Check the unit: EU per vial, EU per mg and EU per mL are not interchangeable.
  • Sterile does not mean endotoxin-free. Killing bacteria does not remove the endotoxin they leave behind.
  • Of nine labs we checked, seven offer some kind of sterility test. Only three name USP <71>: Vanguard Laboratory, Gold Standard Analytics and Chromate.

Three tests, three different questions

It helps to keep the three questions apart, because each test answers only its own.

  • Purity (HPLC): what share of the detected material is the expected compound? It is a ratio of peak areas, not a weight, and it does not prove identity on its own. Our HPLC guide covers how the number is calculated.
  • Sterility: is anything alive in the sample that can grow? A sterility test looks for viable bacteria, yeasts and molds.
  • Endotoxin: how much bacterial endotoxin is present? Endotoxin is not alive. It is material from the cell walls of mostly gram-negative bacteria, and FDA’s inspection guidance notes it is released after the cells die.

A sample can pass any one of these and fail another. That is why a purity certificate, however high the number, should never be read as a cleanliness certificate. Our existing guide to reading lab reports touches on this; here we go through the two microbiological tests in detail.

What sterility testing actually is

The compendial test: USP <71>

USP <71> Sterility Tests is one of the general chapters harmonized between the U.S., European and Japanese pharmacopoeias (the harmonized text appears in ICH Q4B Annex 8). In outline, the harmonized text sets out:

  • Two methods. Membrane filtration, used whenever the product allows it, passes the sample through a filter with a nominal pore size no greater than 0.45 µm that is proven to retain microorganisms. Direct inoculation, used when filtration isn’t suitable, adds the sample straight into the culture media.
  • Two media. Fluid thioglycollate medium, incubated at 30–35 °C, mainly for anaerobic bacteria and also aerobic ones. Soya-bean casein digest medium, incubated at 20–25 °C, for fungi and aerobic bacteria.
  • Not less than 14 days. The inoculated media are incubated for at least 14 days and observed during that time. Growth means the sample fails. No growth means it complies.

That 14-day incubation is why labs that run USP <71> often issue a preliminary certificate first. Vanguard, for example, says it may send a preliminary COA with sterility marked pending, then update the same report when the incubation is done.

The rapid alternatives labs actually sell

Several peptide-testing labs offer faster tests under the same “sterility” heading:

  • PCR screens look for microbial DNA. Freedom Diagnostics lists “Sterility (PCR)”, and Biogenica Labs says its PCR screen “returns an answer in days rather than the fortnight a compendial culture takes.”
  • DNA-microarray screens detect a panel of microbial contaminants by their DNA. ILS Laboratories calls its test a “Rapid Sterility Screen (DNA Microarray)” with results “in days, not the traditional 14-day incubation period.”
  • Microbial counts. Janoshik’s sterility test is a Total Aerobic Microbial Count plus Total Yeast and Mold Count (TAMC + TYMC), a cultivation test with a pass/fail result and a 14-day average turnaround. It is a count method rather than the USP <71> procedure.
  • Bioburden is a count of how many microbes are present, not a sterility test. Vanguard offers bioburden (USP <61>) for capsules, tablets and other non-injectable forms instead of sterility. Gold Standard sells a 3-day bioburden count “instead of USP <71> sterility or with it.”

Rapid methods are not inherently worse. U.S. regulations for biological products allow non-culture sterility methods, provided they are validated and use controls that show they can detect viable contaminating microorganisms (21 CFR 610.12). The point is narrower: a PCR or microarray result is a different measurement from a USP <71> culture, and a certificate that just says “Sterility: Pass” doesn’t tell you which one you are looking at. A DNA-based method also detects genetic material, not growth, so it answers a slightly different question than a culture does.

What endotoxin testing actually is

LAL, recombinant reagents and USP <85>

The standard endotoxin method uses limulus amebocyte lysate (LAL), an extract of horseshoe crab blood cells that reacts with endotoxin. USP <85> Bacterial Endotoxins Test describes three families of technique: gel-clot, photometric (turbidimetric and chromogenic) and kinetic. FDA’s March 2026 guidance on pyrogen and endotoxin testing covers USP <85>, and USP <161>, which applies the same principles to medical devices rather than drug vials.

Animal-free recombinant reagents are now in the picture too. USP published chapter <86>, Bacterial Endotoxins Test Using Recombinant Reagents, in May 2025, and FDA’s 2026 revision of its guidance removed some LAL-specific wording to accommodate recombinant reagents, with the caveat that users should verify the method suits the product.

Endotoxin units, and why the unit matters

Results are reported in endotoxin units (EU), a measure of endotoxin activity against a reference standard. The unit is where certificates quietly diverge:

  • EU per vial is the total in the container. Janoshik reports EU/vial for lyophilized vials.
  • EU per mg is endotoxin relative to the amount of peptide. ILS reports EU/mg; Gold Standard reports both EU per vial and EU/mg.
  • EU per mL is a concentration in a liquid. Biogenica reports EU per milliliter; Janoshik uses EU/mL for liquid samples.

These numbers can’t be compared directly without knowing the vial size, the peptide content or the reconstitution volume. A result with no unit, or a bare “Pass” with no number and no limit, gives you very little to work with.

Interference and reporting limits

Endotoxin assays can be thrown off by the sample itself. FDA’s guidance devotes much of its attention to inhibition and enhancement, where something in the product suppresses or exaggerates the reaction, and to diluting the sample until that interference is gone. That is why some labs run a positive product control: a spike of known endotoxin into the sample, to show the assay can still detect it. Gold Standard names a positive product control on its method page.

Every assay also has a working range. Janoshik’s standard reporting range is 1–1,000 EU per vial, and it says values below 1 EU per vial are reported as estimates. A figure outside a lab’s stated range is not the same as a measured value inside it.

Sterile does not mean endotoxin-free, and the reverse

The two tests miss each other’s targets, and that is the whole reason both exist.

A sterile sample can still contain endotoxin. FDA’s inspection guide on pyrogens says plainly that “bactericidal procedures such as heating, filtration, or adsorption techniques do not eliminate pyrogens from parenteral solutions,” and that pyrogens are heat stable at the temperature of boiling water. Its later guide on endotoxins describes depyrogenating glassware at temperatures such as 250 °C for 45 minutes, far beyond what kills bacteria. Kill the bacteria in a contaminated solution and the endotoxin they leave behind is still there, so a vial can pass a sterility test and fail an endotoxin test.

A low endotoxin result does not mean sterile. Endotoxin comes mostly from gram-negative bacteria. Yeasts, molds and many other organisms that a USP <71> culture is designed to grow don’t register on an endotoxin test at all. A vial can pass an endotoxin test and fail a sterility test.

How to read the sterility and endotoxin lines on a COA

If a certificate carries these lines, run through this list. If it doesn’t carry them, that is an answer too: the tests were not done on that sample, whatever the purity says.

  1. Is the method named? For sterility, look for “USP <71>”, membrane filtration or direct inoculation, and the incubation period, or else the name of the rapid method (PCR, microarray, TAMC/TYMC). For endotoxin, look for LAL or a recombinant method, and ideally the USP chapter.
  2. Is there a number and a unit for endotoxin? EU per vial, EU per mg or EU per mL, plus the lab’s limit or reporting range.
  3. Is the sterility result pending or final? A preliminary report with sterility pending is normal for a 14-day culture. Make sure you are reading the final version.
  4. Does the lot match? The batch or lot number on the report should match the vial or listing. A clean result on another lot tells you about that lot.
  5. Does the lab’s own record match? Look the report up on the issuing lab’s site. Our step-by-step COA verification guide covers how, and the Janoshik verification guide covers Janoshik’s system.

Which labs offer these tests, and which method each uses

We checked the published service pages of nine labs that come up in research-peptide testing: the seven in our Janoshik alternatives guide, plus Janoshik and Biogenica Labs. The table records only what each lab says on its own site. It is not a quality ranking, and we did not order or audit any test.

LabSterility test, as the lab describes itEndotoxin test, as the lab describes it
Vanguard Laboratory (Olympia, Washington)Sterility (USP 71) for injectables; the lab says sterility requires a 14-day incubation. Bioburden (USP <61>) for non-injectable forms.Endotoxin offered, alone or in its Gold and Elite levels. Method and unit not stated on the peptide-testing page.
Gold Standard Analytics (Houston, Texas)USP <71> membrane filtration, FTM and SCDM, 14 days; reported as no growth / growth. Separate 3-day bioburden count.USP <85> kinetic chromogenic LAL with positive product control; reported as EU per vial and EU/mg.
Chromate (street address not published)Membrane filtration and incubation per USP <71>, aerobic/anaerobic microbes and yeast. Incubation period not stated on the page.Kinetic chromogenic LAL, result in EU. No USP chapter named on the page.
ILS Laboratories (San Diego, California)Rapid Sterility Screen (DNA Microarray), results in days rather than a 14-day incubation. Not USP <71>.USP <85> kinetic chromogenic LAL, reported in EU/mg.
Freedom Diagnostics (Franklin, Tennessee)Sterility (PCR), a PCR screen for microbial contamination. Not USP <71>.Endotoxin screen offered. Method and unit not stated on the services list.
Biogenica Labs (Elmwood Park, New Jersey)PCR screen, “in days rather than the fortnight a compendial culture takes.” Not USP <71>.LAL, USP <85>, reported in endotoxin units per milliliter. Also offers a monocyte activation test (MAT) for pyrogens.
Janoshik Analytical (Prague, Czech Republic)TAMC + TYMC cultivation test, pass/fail, 14-day average turnaround. A microbial-count method, not USP <71>.LAL assay; EU/vial for vials, EU/mL for liquids; standard range 1–1,000 EU/vial.
MZ Biolabs (Tucson, Arizona)Not offered. The lab states: “Purity testing does not test for activity, sterility/endotoxins, heavy metals, or pH.”Not offered (same statement).
Colmaric Analyticals (St. Petersburg, Florida)No peptide sterility service found. Microbiology testing is listed for dietary supplements and food.No peptide endotoxin service found.

Three patterns stand out. First, seven of the nine labs offer some form of sterility test, but only three (Vanguard, Gold Standard and Chromate) name USP <71>. Vanguard and Gold Standard also state the 14-day incubation; Chromate names USP <71> membrane filtration and incubation without giving the period on its services page. The other four use PCR, DNA-microarray or microbial-count methods. Second, seven of the nine also offer endotoxin testing, but they don’t all name the method or the unit. Third, MZ Biolabs is the only lab here that says outright it doesn’t test for either.

Accreditation is a separate question. A lab’s ISO/IEC 17025 accreditation covers only the tests listed on its scope, and for the labs we have checked, peptide testing generally sits outside it. Our ISO 17025 guide and Janoshik alternatives guide go through each lab’s scope.

What Amino Review checks, and the limits

In our vendor reviews, endotoxin and sterility testing is one of four “good testing practice” items. A vendor earns a half-point bonus when those results appear on its published certificates, alongside lab-portal verification, mass-spectrometry identity and heavy-metals testing. As with every certificate we look at, we check the report against the issuing lab’s own records where the lab allows it.

That bonus rewards publishing the tests. It does not mean every lot was tested, and it can’t say more than the certificate does. Whoever ordered the test chose the sample and sent it, and the lab tested what it received. A sterility or endotoxin result describes the vial that was tested, from the lot that was tested, at the time it was tested. It is not a statement about the batch, the vendor’s other products, or a vial that has since been opened.

Frequently asked questions

Does 99% purity mean a peptide is sterile?

No. HPLC purity is the share of detected material that is the expected compound. It does not look for living microorganisms or for endotoxin. Sterility and endotoxin need their own tests, usually on separate, unopened vials.

What is USP <71>?

USP <71> Sterility Tests is the compendial sterility test, harmonized with the European and Japanese pharmacopoeias. The sample is membrane-filtered or added directly to two culture media, fluid thioglycollate medium and soya-bean casein digest medium, which are incubated for not less than 14 days. Any growth is a failure.

Is a PCR or microarray “sterility” result the same as USP <71>?

No. PCR and DNA-microarray screens look for microbial DNA and return results in days. They can be useful, and validated non-culture methods are allowed for some regulated products, but they are a different measurement from a 14-day USP <71> culture. The certificate should name the method used.

What do EU/mg, EU/vial and EU/mL mean on an endotoxin result?

EU is an endotoxin unit. EU per vial is the total in the container, EU per mg is relative to the amount of peptide, and EU per mL is a concentration in a liquid. You can’t compare them directly without the vial size, peptide content or volume.

Can a sterile vial still contain endotoxin?

Yes. Endotoxin is residue from bacterial cell walls, and FDA guidance notes that heating, filtration or adsorption steps that kill or remove bacteria do not eliminate it. A vial can pass a sterility test and still fail an endotoxin test.

Which peptide testing labs run USP <71> sterility?

Of the nine labs we checked on November 12, 2026, Vanguard Laboratory, Gold Standard Analytics and Chromate name USP <71> on their own sites. Freedom Diagnostics and Biogenica Labs offer PCR screens, ILS Laboratories a DNA-microarray screen, and Janoshik a TAMC/TYMC microbial count. MZ Biolabs says it tests for neither sterility nor endotoxin.

The bottom line

A purity number answers one question. Before you read anything into a certificate about cleanliness, check three things: whether sterility and endotoxin were tested at all, which method was used for each, and whether the result has a number, a unit and a lot that match what you are looking at. Then confirm the report with the lab that issued it.

Sources

Facts were checked on November 12, 2026, against the following pages.

  1. ICH Q4B Annex 8, Sterility Test General Chapter (harmonized Ph. Eur./JP/USP text), EMA document EMEA/CHMP/ICH/645592/2008 — EMA PDF
  2. U.S. FDA, Pyrogen and Endotoxins Testing: Questions and Answers, Guidance for Industry (March 2026) — FDA guidance
  3. U.S. FDA, FDA Clarifies Current Thinking on Pyrogen and Endotoxins Testing (USP <86> and recombinant reagents) — FDA announcement
  4. U.S. FDA, Inspection Technical Guide No. 32, Pyrogens, Still a Danger — FDA ITG 32
  5. U.S. FDA, Inspection Technical Guide No. 40, Bacterial Endotoxins/Pyrogens — FDA ITG 40
  6. 21 CFR 610.12, Sterility (eCFR) — eCFR
  7. Health Canada, advisory RA-82930, November 6, 2026 — Canada.ca
  8. Vanguard Laboratory, peptide testing — vanguardlaboratory.com/peptide-testing
  9. Gold Standard Analytics, peptide testing — goldstandardanalytics.com
  10. Chromate, analytical services — chromate.org/services
  11. ILS Laboratories, peptide QC testing — ils-lab.com
  12. Freedom Diagnostics, testing services — freedomdiagnosticstesting.com
  13. Biogenica Labs, research COA testing — biogenicalabs.com/research-coa
  14. Janoshik Analytical, sterility testing (TAMC+TYMC) — janoshik.com; endotoxin analysis — janoshik.com and Janoshik Help Center
  15. MZ Biolabs, COA testing — mzbiolabs.com/coa-testing
  16. Colmaric Analyticals, homepage — colmaricanalyticals.com
  17. Amino Review: Janoshik Alternatives, Are Peptide Testing Labs ISO 17025 Accredited?, What 99% Peptide Purity Means, How to Verify a Peptide COA

Research use only: products discussed here are sold by third-party vendors, labeled for research use only, and are not approved drugs. This guide explains what laboratory tests measure and how to read them; it is not medical, legal, or purchasing advice, and it is not an endorsement of any laboratory. See our full disclaimer. Corrections are welcome at contact@aminoreview.com.