Last updated November 24, 2026. Amino Review does not run lab tests. Examples come from published lab explanations and public research discussions, cited at the end. Research use only — not medical advice.
A peptide certificate of analysis (COA) usually carries three numbers that look like one verdict: purity, identity, and a measured amount in milligrams. They answer three separate questions — is it clean, is it the right compound, and how much is actually in the vial — each measured by a different test.
Key takeaways
- HPLC purity cannot prove identity. A vial can test 99.67% pure and still hold a different peptide than the label says.
- Identity is a mass-spectrometry job. LC-MS compares the sample’s mass — and, with tandem MS, its fragment pattern — against a reference standard.
- One peptide shows several m/z peaks. Electrospray ionisation makes multiply charged ions; the deconvoluted neutral mass is the number to compare with the expected mass.
- Monoisotopic and average mass differ. Comparing one against the other is the most common reading error on an identity line.
- Net peptide content is the actual peptide in the vial. Salt counter-ions, residual water and fill variance all sit inside the gross weight on the label, and none shows up in a purity figure.
- A complete COA carries all three lines — purity by HPLC, identity by LC-MS, and a measured amount — for the same lot, verified with the issuing lab.
Three separate questions
| Question | Test that answers it | What it reports |
|---|---|---|
| Is the material clean? | HPLC with UV detection | Purity as a percentage of total peak area |
| Is it the right compound? | LC-MS or LC-MS/MS identity | Expected vs observed mass, pass/fail against a reference standard |
| How much peptide is in the vial? | Net peptide content assay | Milligrams per vial, and percentage of the label claim |
Our guide Peptide Purity 99%: What It Means and What It Misses covers the first row, and How to Verify a Peptide COA covers confirming the document itself is genuine.
Why HPLC purity can’t prove identity
HPLC separates a sample’s components and measures how much of the detected signal belongs to the main peak. A 99% result means the material is nearly all one thing. It does not say what that thing is.
The clearest public example comes from a case discussed by Derek Pruski in June 2026. A vial labelled Adamax, 5 mg, was tested by a third-party lab: identity failed, purity 99.67% by HPLC-UV, net content 6.03 mg — and the compound in the vial was N-Acetyl Semax, a different peptide entirely. Very nearly pure, slightly overfilled, and completely the wrong compound. Purity and amount both passed; identity failed, and identity was the only line that could catch it. A purity-only COA is therefore incomplete.
How LC-MS proves identity: the three locks
Mass spectrometry identifies a compound by weighing it. Chromatography separates the sample, then the spectrometer ionises the molecules and measures their mass-to-charge ratio. A lab confirms identity against a reference standard — a verified sample of the claimed compound — and can only test compounds for which it holds a standard and a validated method.
A strong identity check has three locks, each foolable on its own: retention time (the sample’s main peak must come off the column at the same time as the standard — weak alone, but a mismatch rules a sample out); intact mass (observed mass must match expected mass within the lab’s stated tolerance); and fragment ions (in tandem MS, LC-MS/MS, the instrument breaks the molecule apart and reads the fragment pattern, the b and y ion series, which reflects the amino acid sequence — two compounds can share an intact mass, but far fewer share a fragment pattern). All three agreeing is a strong identity claim; retention time alone, or a bare “identity: confirmed” with no numbers, is thin.
Reading the identity line, step by step
Expected vs observed mass. Expected mass is the theoretical molecular weight of the claimed compound, usually the monoisotopic mass; observed mass is what the instrument measured. The two should agree within the lab’s stated tolerance — on a high-resolution instrument, mass accuracy better than five parts per million is routine.
Why one peptide shows several m/z peaks. Electrospray ionisation gives each molecule several protons, so one peptide appears at several mass-to-charge (m/z) values, one per charge state: observed m/z for charge state n is (M + n × 1.00728) ÷ n, where M is the neutral mass. A peptide of monoisotopic mass 4113.6 daltons appears at m/z 1372.2 triply charged and 1029.4 quadruply charged. Two charge states agreeing on the same deconvoluted mass is a much stronger claim than one.
Monoisotopic vs average mass. The most common reading error. Monoisotopic mass uses the lightest isotope of each atom; average mass weights all isotopes by natural abundance. For a peptide of a few thousand daltons the two differ by roughly a dalton or more, so mixing them makes the numbers disagree even when the identity is correct. Both figures must be the same kind of mass, and the lab must state its tolerance — without either, the result is not checkable.
What intact mass cannot prove
A matching intact mass rules out a great deal and confirms less than people assume. Mass-neutral substitutions are invisible to it: a D-amino acid in place of an L-amino acid, or a scrambled disulfide pairing, changes no atom count and therefore no mass. Same-mass isomers exist — two different sequences can share a mass, and an unchanged mass with a shifted retention time is the classic sign of one. Small modifications shift the mass in recognisable ways: +1 dalton for deamidation, +16 for oxidation, −18 for dehydration or succinimide formation. Where identity is genuinely in doubt, LC-MS/MS fragmentation or a peptide-mapping digest is the next step. Intact mass is the first lock, not the whole check.
Net peptide content: gross weight vs actual peptide
The amount line decides what is actually in the vial. A vial labelled 10 mg holds 10 mg of powder, and that powder is not all peptide. Salt counter-ions: peptides purified by reversed-phase chromatography are typically isolated as trifluoroacetate (TFA) salts, unless a deliberate exchange to acetate was done. Counter-ions add roughly 5% to 17% of the weighed mass — MOTS-c is 2,174.6 daltons as a free base and 2,288.6 as a TFA salt, so a vial labelled 10 mg of TFA salt holds roughly 9.5 mg of peptide. Residual water and solvent: a lyophilised cake retains moisture, and peptides are hygroscopic enough that the retained fraction changes with handling and storage; neither is declared on most certificates. Fill variance: how much powder actually went into the vial. A registry analysis of 1,847 lab certificates from 69 vendors (August 2026) found the median vial held 6.9% more than its label claimed, with 84.7% above label — but individual results ranged from a gonadorelin vial labelled 5 mg that measured 2.12 mg to a cagrilintide vial labelled 10 mg that measured 19.4 mg, while purity beside those measurements was unremarkable.
The arithmetic is simple once the net content figure is known: a 10 mg vial at 4% water and 8% TFA holds 10.0 × 0.88 = 8.8 mg of peptide — a 12% shortfall against the label with a perfectly clean purity figure. Net content can also read over 100% of the label claim when a vial is overfilled; purity, a percentage of detected peak area, cannot exceed 100%. Overfill is far more common than underfill, and an overfilled vial is not generosity — it is the same absence of fill control pointing the other way. The reverse also happens: a mazdutide sample labelled 20 mg assayed at 15.18 mg while testing 99.80% pure.
Content is measured against a certified reference standard — or by amino acid analysis or nitrogen determination. A certificate should say whether its mass is gross powder or net peptide; many do not. A certificate reporting 10.7 mg of gross powder against a 10 mg label may describe a vial dead-on for peptide, or one genuinely overfilled. If it does not say which it reports, treat it as gross and ask.
Checklist: before you trust the identity line
- Method named. LC-MS or LC-MS/MS, not “identity confirmed” with no method.
- Expected and observed mass both printed, of the same mass type (monoisotopic or average), with a stated tolerance.
- At least two charge states shown, agreeing on the same deconvoluted mass.
- Reference standard identified — the lab compared the sample against a verified standard of the claimed compound, not a library spectrum alone.
- Purity and content on the same report, same lot, so all three questions are answered for the same sample.
- Lot number matches the vial you are holding, and the report is verified with the issuing lab — our guide How to Verify a Peptide COA walks through that check.
- No unexplained mass shift (+1, +16, −18) and no retention-time mismatch left unaddressed.
If a report fails the first two checks, the identity result is a claim, not evidence. Ask the vendor for the full LC-MS report — our guide Janoshik Alternative: 7 Peptide Testing Labs Compared sets out what to look for in a lab.
Sources
- Derek Pruski, “When Adamax Came Back As N-Acetyl Semax: How Third-Party Labs Actually Identify Peptides,” Substack, 12 June 2026. https://derekpruski.substack.com/p/when-adamax-came-back-as-n-acetyl
- AskPeptide, “Does an LC-MS run identify an impurity or only separate it?” asked 3 July 2026. https://www.askpeptide.net/q/1207/does-an-lc-ms-run-identify-an-impurity-or-only-separate-it/
- AskPeptide, “How much of the gross mass of a 40 mg tirzepatide vial is actually peptide?” asked 27 May 2026. https://www.askpeptide.net/q/2941/how-much-of-the-gross-mass-of-a-40-mg-tirzepatide-vial-is-actually-pepti/
- AskPeptide, “What counter-ion should I expect on a CPC liraglutide lot?” asked 12 November 2025. https://www.askpeptide.net/q/4450/what-counter-ion-should-i-expect-on-a-cpc-liraglutide-lot/
- Peptigrity, “Net Peptide Content: Why a 10mg Vial Isn’t 10mg,” published 2 July 2026. https://peptigrity.com/blog/peptide-net-content-why-10mg-isnt-10mg
- Goodtides, “1,847 Lab Certificates: 84.7% of Vials Miss Their Label,” data computed 5 August 2026. https://goodtides.shop/peptide-vial-overfill-study.html
- Gold Standard Analytics, “Peptide Purity Explained,” updated 27 October 2026. https://www.goldstandardanalytics.com/peptide-purity
- Amino Review, “HPLC for Peptides Explained.” https://aminoreview.com/hplc-for-peptides-explained/
- Amino Review, “Peptide Purity 99%: What It Means and What It Misses.” https://aminoreview.com/peptide-purity-99-percent/
- Amino Review, “How to Verify a Peptide COA: 8 Steps With Real Examples.” https://aminoreview.com/how-to-verify-peptide-coa/
- Amino Review, “Janoshik Alternative: 7 Peptide Testing Labs Compared.” https://aminoreview.com/janoshik-alternative/
Related reading on Amino Review: How to Read Third-Party Lab Test Results and Peptide Endotoxin and Sterility Testing.